IT Cert Ready

CompTIA

Network+

Exam code: N10-009

Start practicing

About this certification

Network+ is a CompTIA certification. Exam code N10-009. IT Cert Ready offers 1,188 practice questions with domain quizzes, full mock exams, and detailed explanations. Practice by official domain with 5 blueprint-aligned domains.

Official exam domain weights

Verified blueprint weights from the official exam outline.

  • Domain 1 · Networking Concepts · 23%
  • Domain 2 · Network Implementation · 20%
  • Domain 3 · Network Operations · 19%
  • Domain 4 · Network Security · 14%
  • Domain 5 · Network Troubleshooting · 24%

Sample Network+ practice questions

Preview realistic multiple-choice items from the IT Cert Ready question bank. Expand each answer for the correct choice and explanation—the same format used in domain quizzes and mock exams.

  1. Sample question 1 · Network Troubleshooting (24%)

    Hartwell & Crane LLP, a mid-sized law firm with 120 attorneys across two floors, recently deployed IP phones at every workstation as part of a unified communications rollout. The network team ran new horizontal cabling from the IDF to each desk, reusing a spool of Cat5e cable they found in storage. After installation, attorneys on the second floor report that their IP phones power on intermittently and drop calls frequently, while first-floor phones operate normally. The network administrator checks the switch and confirms that all second-floor ports are configured for PoE. Cable lengths on both floors are under 80 meters. The administrator then uses a cable certifier on a sample of second-floor runs and discovers that the wire pairs do not meet the current TIA-568 standard for PoE power delivery. Which physical layer issue MOST likely explains why the second-floor IP phones are experiencing intermittent power and call drops despite the switch ports being PoE-enabled?

    • A. The Cat5e cable in storage is rated for data transmission but lacks the conductor gauge and pair resistance specifications required to sustain PoE current over the run lengths used, causing voltage drop and intermittent device power.
    • B. The switch ports on the second-floor IDF are configured for 802.3af instead of 802.3at, limiting available wattage to the IP phones and causing them to reset under load.
    • C. The IP phones are experiencing crosstalk from adjacent data cables in the same conduit, which disrupts the PoE negotiation signal and causes the phones to lose power.
    • D. The second-floor runs exceed the maximum segment length for PoE delivery, causing attenuation of the DC power signal before it reaches the powered devices.
    View answer & explanation

    Correct answer: A. The Cat5e cable in storage is rated for data transmission but lacks the conductor gauge and pair resistance specifications required to sustain PoE current over the run lengths used, causing voltage drop and intermittent device power.

    [Domain 5 - Network Troubleshooting, Subtopic 5 - Network Troubleshooting - Area 1 - Cable type mismatches] Core Concept: Given a scenario, troubleshoot common cabling and physical interface issues. centers on cable type mismatches as defined in the official (ISC)² exam outline. Correct Answer (A): The Cat5e cable in storage is rated for data transmission but lacks the conductor gauge and pair resistance specifications required to sustain PoE current over the run lengths used, causing voltage drop and intermittent device power. Why the other options are incorrect: Option B: While an 802.3af vs. 802.3at mismatch could limit wattage, the scenario states the administrator confirmed PoE is configured on all ports and the cable certifier — not a switch audit — revealed the root cause; a PoE standard mismatch would not be detected by a cable certifier flagging TIA-568 pair resistance failures. Option C: Crosstalk affects data signal integrity and would manifest as CRC errors or reduced throughput, not as intermittent power loss; PoE power delivery operates on DC current across all four pairs and is not disrupted by near-end crosstalk in the way data signals are. Option D: The scenario explicitly states all cable runs are under 80 meters, well within the 100-meter channel limit; PoE voltage drop is governed by conductor resistance, not segment length alone, and the cable certifier finding points to resistance specification failure rather than an excessive-length violation.

  2. Sample question 2 · Network Troubleshooting (24%)

    Arcturus DevOps, a mid-sized cloud application team operating across two continents, has deployed IP phones at its North American office using a new 48-port managed switch. The switch supports PoE+ (IEEE 802.3at). After installation, technicians report that roughly one-third of the phones power on normally, while the remaining phones cycle on and off repeatedly or fail to power on at all. All phones are the same model and are connected with newly purchased patch cables. The switch's PoE budget is listed as 370 watts total. Each phone is rated at 15.4 watts. A network engineer at Arcturus DevOps is tasked with identifying the cause of the intermittent PoE failures. Which finding MOST likely explains the symptom?

    • A. The patch cables are Cat6a, which is incompatible with PoE+ signaling and causes power negotiation to fail on affected ports.
    • B. The phones are requesting IEEE 802.3af Class 3 power, but the switch ports are locked to 802.3at Class 4 delivery, causing a class mismatch rejection.
    • C. The total PoE power draw from all 48 phones at 15.4 watts each exceeds the switch's 370-watt PoE budget, causing the switch to deny power to ports beyond its capacity.
    • D. The switch's uplink port is connected with a crossover cable, which disrupts the control plane and prevents PoE allocation tables from updating.
    View answer & explanation

    Correct answer: C. The total PoE power draw from all 48 phones at 15.4 watts each exceeds the switch's 370-watt PoE budget, causing the switch to deny power to ports beyond its capacity.

    [Domain 5 - Network Troubleshooting, Subtopic 5 - Network Troubleshooting - Area 1 - Cable type mismatches] Core Concept: Given a scenario, troubleshoot common cabling and physical interface issues. centers on cable type mismatches as defined in the official (ISC)² exam outline. Correct Answer (C): The total PoE power draw from all 48 phones at 15.4 watts each exceeds the switch's 370-watt PoE budget, causing the switch to deny power to ports beyond its capacity. Why the other options are incorrect: Option A: Cat6a is fully compatible with PoE and PoE+ standards; the higher-quality cabling actually reduces resistive power loss over the cable run and does not interfere with power negotiation in any way. Option B: IEEE 802.3at (PoE+) switches are backward compatible with 802.3af devices; a class mismatch between af and at does not cause rejection — the switch simply delivers the lower class power level requested by the PD. Option D: A crossover cable on an uplink port would affect data-plane connectivity for that uplink segment but would not disrupt the local PoE allocation engine, which operates independently at the physical port level for each connected PD.

  3. Sample question 3 · Network Troubleshooting (24%)

    Crestfield Community Bank operates a single headquarters building with 220 employees across four floors. The network team recently deployed IP phones to all desks using Power over Ethernet from a new access layer switch. After one week of operation, the help desk metrics dashboard shows a spike in ticket volume: 34 phones on the third floor are intermittently rebooting, and the affected switch port counters show runts on the ingress side of those ports. The PoE budget report from the switch management interface shows the third-floor switch is drawing 98% of its rated PoE wattage. The cabling to those ports was installed during the original building construction and is documented as Cat 3. Based on the interface metrics and infrastructure documentation, which combination of issues is MOST likely responsible for the phone reboots and runt frames on the third-floor switch ports?

    • A. The Cat 3 cabling cannot reliably carry PoE current at the required wattage for IP phones, and the resulting voltage drop causes phones to lose power mid-operation and restart, while the power interruption also produces incomplete frames recorded as runts.
    • B. The switch PoE budget is oversubscribed, causing the switch to cycle power to individual ports to shed load, which interrupts phone operation and generates runt frames as phones lose power during frame transmission.
    • C. The Cat 3 cable's lower bandwidth rating causes signal attenuation that prevents the phones from completing the PoE negotiation handshake, so phones repeatedly attempt to power on and fail, producing runt frames during each failed attempt.
    • D. The IP phones are configured to request 802.3bt Class 6 power, which exceeds what the switch can deliver per port, causing the switch to deny power and force the phones into a reboot loop while generating runts from incomplete LLDP-MED frames.
    View answer & explanation

    Correct answer: B. The switch PoE budget is oversubscribed, causing the switch to cycle power to individual ports to shed load, which interrupts phone operation and generates runt frames as phones lose power during frame transmission.

    [Domain 5 - Network Troubleshooting, Subtopic 5 - Network Troubleshooting - Area 1 - Cable type mismatches] Core Concept: Given a scenario, troubleshoot common cabling and physical interface issues. centers on cable type mismatches as defined in the official (ISC)² exam outline. Correct Answer (B): The switch PoE budget is oversubscribed, causing the switch to cycle power to individual ports to shed load, which interrupts phone operation and generates runt frames as phones lose power during frame transmission. Why the other options are incorrect: Option A: While Cat 3 is unsuitable for modern Ethernet standards, PoE power delivery relies on DC current over the copper pairs rather than the cable's bandwidth rating; the primary constraint identified by the switch's own PoE budget report is capacity exhaustion, not cable resistance causing voltage drop across a short in-building run. Option C: PoE negotiation uses IEEE 802.3 physical layer signaling that Cat 3 cannot reliably support for data, but the scenario states the phones are already operational and intermittently rebooting rather than failing to power on initially, which points to a runtime power interruption rather than a negotiation failure. Option D: The scenario provides no evidence that the phones are requesting Class 6 power levels, and the switch PoE budget report showing 98% utilization across all ports is a more direct and measurable indicator of aggregate budget exhaustion than a per-port class mismatch.

  4. Sample question 4 · Network Troubleshooting (24%)

    Crestfield Healthcare Network, a 250-bed regional hospital system subject to HIPAA requirements, is conducting a continuous improvement review of its wired infrastructure after its SIEM flagged a sustained increase in interface error rates on the nursing station access layer. The network operations team pulls a 30-day trending report showing that four switch ports serving nurse call stations in Wing C have progressively worsening attenuation metrics, with received optical power on the associated SFP transceivers dropping from -3 dBm at baseline to -11 dBm over the review period. The runs use plenum-rated Cat 6A UTP cable routed through ceiling spaces shared with HVAC ducting. Staff report that the nurse call stations intermittently lose connectivity during peak HVAC operation hours. No cable replacements or moves have occurred in Wing C. Given the SIEM trending data showing progressive signal degradation correlated with HVAC operation, which physical-layer condition BEST accounts for the symptoms, and what should the team investigate first?

    • A. The Cat 6A UTP cable runs are experiencing crosstalk from adjacent power cables in the ceiling plenum, which worsens when HVAC motors introduce electrical noise; the team should inspect cable routing for proximity to high-voltage conductors and add separation or shielded cable where needed.
    • B. The SFP transceivers are reaching end-of-life and their laser output is degrading over time; replace all four transceivers and retest received power levels.
    • C. The Cat 6A UTP runs are experiencing thermal expansion and contraction from HVAC airflow cycling, which is stressing connectors and patch panel terminations, increasing contact resistance and causing the progressive attenuation increase; the team should inspect and re-terminate all connectors on the affected runs.
    • D. The plenum-rated Cat 6A cable has a higher attenuation-per-meter rating than standard Cat 6A due to its fire-retardant jacket compound, and the runs exceed the recommended length for the installed transceivers; shorten the cable runs or install intermediate switches.
    View answer & explanation

    Correct answer: C. The Cat 6A UTP runs are experiencing thermal expansion and contraction from HVAC airflow cycling, which is stressing connectors and patch panel terminations, increasing contact resistance and causing the progressive attenuation increase; the team should inspect and re-terminate all connectors on the affected runs.

    [Domain 5 - Network Troubleshooting, Subtopic 5 - Network Troubleshooting - Area 1 - Cable type mismatches] Core Concept: Given a scenario, troubleshoot common cabling and physical interface issues. centers on cable type mismatches as defined in the official (ISC)² exam outline. Correct Answer (C): The Cat 6A UTP runs are experiencing thermal expansion and contraction from HVAC airflow cycling, which is stressing connectors and patch panel terminations, increasing contact resistance and causing the progressive attenuation increase; the team should inspect and re-terminate all connectors on the affected runs. Why the other options are incorrect: Option A: Crosstalk from power cables would produce near-end or far-end crosstalk errors and elevated noise floor rather than a measurable decline in received optical power on SFP transceivers, which are optical interfaces unaffected by electromagnetic interference on copper pairs in the same ceiling space. Option B: Simultaneous degradation of four separate transceivers at the same rate over the same period is statistically unlikely as a coincidental end-of-life event; the HVAC correlation strongly implicates an environmental mechanical cause rather than independent transceiver failures. Option D: Plenum-rated Cat 6A cable does have slightly higher attenuation per meter than non-plenum variants, but this is a fixed characteristic present from installation; it would not cause a progressive decline in signal strength over 30 days unless the runs were already at or beyond specification limits, which the baseline measurement of -3 dBm indicates was not the case.

  5. Sample question 5 · Network Troubleshooting (24%)

    Hartwell Indemnity Group, a mid-sized insurance provider, is conducting a BCP/DR tabletop exercise at its regional data center. During the exercise, the network team simulates a failover to a backup switch stack. After the failover, technicians report that several IP phones in the claims processing wing have lost power and gone offline, even though the backup switch stack is operational and the phones show link lights. The backup switches were recently procured as a cost-saving measure and are rated for 802.3af PoE. The primary switches had been upgraded to 802.3bt prior to the disaster. The phones themselves are standard 802.3af-compatible devices. A technician checks the switch logs and finds no PoE fault messages. The network manager suspects a policy exception was granted to defer upgrading the backup switches to 802.3bt parity with the primary stack. Given the scenario, what is the most likely root cause of the IP phones losing power after failover to the backup switch stack, and what corrective action should the network team recommend?

    • A. The backup switches are delivering 802.3af PoE, but the phones require 802.3bt power levels because the primary switches had conditioned the phones to negotiate higher wattage; the fix is to reset the phones to factory defaults.
    • B. The backup switches lack sufficient PoE budget allocation per port because the cost-saving procurement resulted in switches with a lower total PoE wattage budget than the primary stack, causing power to be denied to some ports even though per-port standards match; the fix is to audit and increase the PoE budget or reduce the number of powered devices per switch.
    • C. The link lights indicate a physical connection, but the backup switches are using straight-through cables where crossover cables are required for phone uplinks, causing PoE negotiation to fail silently.
    • D. The IP phones are not receiving power because the backup switches have PoE disabled by default on access ports as a security policy exception; the fix is to enable PoE on the relevant access ports in the switch configuration.
    View answer & explanation

    Correct answer: D. The IP phones are not receiving power because the backup switches have PoE disabled by default on access ports as a security policy exception; the fix is to enable PoE on the relevant access ports in the switch configuration.

    [Domain 5 - Network Troubleshooting, Subtopic 5 - Network Troubleshooting - Area 1 - Cable type mismatches] Core Concept: Given a scenario, troubleshoot common cabling and physical interface issues. centers on cable type mismatches as defined in the official (ISC)² exam outline. Correct Answer (D): The IP phones are not receiving power because the backup switches have PoE disabled by default on access ports as a security policy exception; the fix is to enable PoE on the relevant access ports in the switch configuration. Why the other options are incorrect: Option A: 802.3af and 802.3bt are negotiated per-session and phones do not retain a higher wattage requirement from a previous switch; resetting phones to factory defaults would not resolve a switch-side configuration issue. Option B: A PoE budget exhaustion scenario would typically generate log warnings or alerts and would affect only some ports progressively, not all phones simultaneously at failover; the scenario describes no such log entries. Option C: Modern switches use Auto-MDIX, making crossover versus straight-through cable type irrelevant for standard copper Ethernet uplinks; this would not cause a PoE-specific failure while link lights remain active.

Network+ exam prep FAQ

What is the passing score for the Network+ exam?
The Network+ exam uses a scaled score. A common published passing threshold is 720 on a scale of 100–900. Always confirm the current requirement on the official CompTIA exam guide before you sit for the test.
How many questions are on the Network+ certification exam?
The live Network+ exam typically includes 90 questions (maximum) with about 90 minutes on the clock. Formats can vary by delivery mode and exam update.
How do domain quizzes help with Network+ exam prep?
Domain quizzes on IT Cert Ready let you practice Network+ one blueprint domain at a time across 5 official exam domains. You get immediate feedback, detailed explanations, and can revisit weak areas before taking a full timed mock exam.
How many Network+ practice questions are on IT Cert Ready?
IT Cert Ready includes 1,188 published Network+ practice questions with domain quizzes, full-length mock exams, and answer explanations mapped to the official outline.